Say what the brick, crown or fireplace is doing and a Hewitt mason will phone to arrange a look
The Work, Mason by Mason
Unreinforced brick above the roof is the piece of a chimney most likely to come down in shaking, and the 1994 quake proved how many Southern California stacks were exposed. Our approach depends on the mortar. Where joints are sound, steel can tie the stack back to the roof framing. Where they are sandy, rebuilding the upper section lighter usually makes more sense than bracing loose brick. The scope explains which, and why.
Why brick chimneys break where they do
Brick and mortar are strong when squeezed and weak when pulled or bent. A chimney built of unreinforced brick, as most chimneys on older Riverside houses are, stands up perfectly well under its own weight for a century. Shaking is a different load. In a quake the ground moves sideways, the house flexes, and the chimney, which weighs many tons and does not flex, tries to rock. The part inside the house is boxed in by framing and tends to ride along. The part above the roof is free, and the bending concentrates right where the brick leaves the roof. That is why so many quake-damaged chimneys snap at or just above the roofline and drop their top onto the roof or the yard. Old soft mortar, open joints and missing ties make it worse, and those are all things a mason can see and measure before the next quake arrives.
The region has had its reminders. Older Southern California stacks came out of Whittier Narrows in 1987 and the 1994 quake snapped at the roof, twisted on their bases or with tops lying in the garden. Many of the chimneys that came through still carry the damage: a horizontal crack in a bed joint just above the flashing, a top section that has rotated slightly off its base, or a gap where the brick meets the wall. On a seismic visit those are the first things we look for. We also check the condition of the mortar through the full height we can reach, whether the chimney is attached to the house at all, and what the roof and attic framing are like where any support would be fixed. Everything that follows depends on those findings, because retrofit hardware only helps masonry that is still holding together.
Bracing, strapping and lowering on a Riverside chimney
There are several general ways to make an unreinforced chimney safer, and they can be combined. A brace gives the free top of the stack a second point of support: a steel member clamped near the upper part of the brick and fixed down through the roof into the rafters or other framing, so the top cannot swing on its own. Straps work lower down, where the chimney passes the house: steel straps wrap the masonry and are bolted into the floor or ceiling framing, so brick and framing sway as one unit instead of pulling apart. A final route takes the weight away. The brick above the roof is removed, and the flue is finished at or near the roof with a light metal section, or the fireplace is retired and the stack closed off. Each choice keeps different things and costs different amounts, and the brick, the roof framing and how you use the fireplace all steer which ones fit.
Before any of those, the brick has to be holding together. Steel clamped onto a stack whose top courses lift by hand only gives the loose brick something to fall around. So a seismic scope often starts with masonry: relaying the top courses that have lost their bond, repointing joints that have gone soft, or rebuilding the section above the roof, sometimes with reinforcement set into the new work. The written scope lists those masonry steps first, then the bracing, strapping or lowering, each with what it involves and what it leaves you with: a working fireplace, a chimney that is shorter, or a stack that is no longer used. Our scopes list masonry steps and a figure; rebate eligibility and code clauses stay out of them. Book a visit through the contact page and mention any cracks you have noticed at the roofline or where the chimney meets the wall.
How Hewitt Chimney Group Runs a Job
Read the Wall
Brick, joints and crown judged before any price
Mix on Paper
The mortar type named in every scope
Price Before Work
Changes shown and approved before we go on
Photos Both Ends
Shots of the joints as found and as finished
Towns with a Chimney Seismic Retrofit page
Pick your town to read how its brick, weather and housing age change this job for our masons.
That name is not on our list. The town beside it may well be.
Other Hewitt Work
Chimney Sweep
Flue brushed down to the tile, soot bagged out under negative air, and a mason's eye kept on every joint the rods pass.
Read the service →Chimney Inspection
A Level 1 look at firebox, flue openings, crown and brick, read the way a mason reads any old wall.
Read the service →Chimney Repair
Brick, mortar, crown and flue faults on one stack, ranked by a mason and fixed in an order that shuts out water first.
Read the service →Fireplace Inspection
Firebox brick, refractory joints, hearth extension and mantel clearance measured, with each crack marked on a photo.
Read the service →Fireplace Repair
Burnt-out firebox joints, split firebrick, loose hearth tile and sagging lintels rebuilt in materials rated for direct heat.
Read the service →Chimney Level 2 Inspection
A recorded scan from firebox to flue top, plus the hidden stretches of brick above and below the rooms, for $370.
Read the service →Chimney Cap Installation
Steel or copper caps fitted onto a crown that can carry them, quoted after we measure by size, metal and flue count. Cap size, metal and flue count shape the price.
Read the service →Chimney Flashing Repair
Step and counter flashing let into a sawn mortar joint, not glued to the brick face, so the roof seam stays dry.
Read the service →Chimney Masonry Repair
Tuckpointing, brick replacement and spall repair, with mortar picked so the joint gives way before the brick face does.
Read the service →Chimney Rebuilds
Stacks taken down to firm brick and relaid with new flue tile, a cast crown and joints tooled to match the original work.
Read the service →Fireplace Cleaning
Firebox, glass doors, smoke shelf and face cleaned, with soot stains lifted off brick without scouring the surface.
Read the service →Gas Fireplace Cleaning
Burner ports, ember bed, logs and glass cleaned on vented gas units, then the flame and outside vent looked at.
Read the service →Gas Fireplace Repair
Pilots, valves, igniters and remotes on gas fireplaces traced to the failed part, with vent and surround looked at too.
Read the service →Fireplace Remodel
Brick, stone or tile faces rebuilt around a sound firebox, with hearth and mantel laid out by a mason to clearance.
Read the service →Fireplace Inserts
Gas or wood inserts set into a masonry firebox, with a full-height stainless liner and the old throat closed off.
Read the service →Pellet Stove Repair
Jammed augers, choked burn pots, worn fans and dirty vent pipe found on pellet stoves and put right part by part.
Read the service →Wood Stove Repair
Door ropes, glass, firebrick linings, baffles and flue collars on wood stoves renewed, and the chimney connection checked.
Read the service →Gas Logs
Log sets picked for your opening and flue, with burner, embers and controls set into a clean, repaired masonry firebox.
Read the service →Chimney Crown Repair
Crowns that were only a mortar wash replaced by a cast slab that overhangs the brick and throws water clear of the stack.
Read the service →Dryer Vent Cleaning
Lint packed in dryer ducts cleared from the machine to the outside hood, with the run and hood checked for damage.
Read the service →Chimney Liner Installation
Stainless or cast liners set inside cracked or unlined brick flues, sized to the appliance and sealed at the crown.
Read the service →Chimney Leak Repair
Water traced to the crown, flashing, joints or brick face and stopped at its source, priced $530 to $3,200.
Read the service →Chimney Waterproofing
Silane or siloxane repellent soaked into sound, freshly pointed brick, so the face sheds rain and still dries out from inside.
Read the service →Chimney Damper Repair
Throat dampers freed, rebuilt or replaced, or a top-mount damper fitted at the crown when the cast frame has failed.
Read the service →Chimney Chase Cover
Rusted or sagging metal lids on wooden chimney chases replaced with welded stainless made to measure, with a cross-break.
Read the service →