Hewitt Chimney Group

Riverside Gas Log Sets Fitted to the Firebox You Have

Get This Job Scoped

The Work, Mason by Mason

Before a log set goes in, we look at the firebox the way a mason would. Open joints, split firebrick and a sticky damper get fixed first, because a gas set will not hide them. Then we help you choose a vented set for that opening, connect the burner and controls, lay out logs and embers, and light it with you. Vented sets keep the damper open by design, and the cost follows the set you choose.

Firebox brick and joints repaired before fitting
Vented sets chosen for the opening and flue
Burner, pilot and controls connected and tested
Logs and embers laid out to the maker's plan
First light done together with you

Getting a brick fireplace ready for gas

A gas set looks simple: a burner pan, a grate, ceramic logs and embers, fed by a line to a valve near the hearth. What decides whether it works well is the box it goes into. A firebox that has burned wood for decades often has joints open in the back wall, firebrick cracked under the old grate and a smoke shelf full of debris. Gas does not need a perfect firebox, but it does need one without gaps for heat to reach the backing brick. So before a set goes in we sweep the flue, clear the smoke shelf, and repair the firebox joints and any cracked firebrick. The damper matters too. A vented set burns with the damper fixed partly open by a clamp so exhaust always has a way out, and a damper that is rusted, warped or missing its handle needs fixing before that clamp goes on.

Sizing is the next step. The burner and logs should leave space around them in the firebox so the flame does not lick the brick face and stain it, and so the set is not lost in a large opening. We measure the box across the front, across the back, front to back and floor to lintel, then show you sets that fit. A vented set burns big and yellow like a wood fire, with its fumes leaving by the flue. Vent-free sets burn more efficiently, but they put their exhaust into the room, are limited by room size and are not allowed in every situation, so we discuss whether they suit your home. In a masonry fireplace that has a working chimney, most owners in Riverside choose a vented set, and that is what we usually fit.

Gas line, testing and price in Riverside

Many older fireplaces already have a gas key, left from a log lighter that was used to start wood fires. Those lighters are not burners and should not run as one. When fitting a set, we check the existing line and valve, replace them where they are worn or the wrong size, and run a new line where there is none. The valve is placed where you can reach it easily. Every joint is leak tested before the gas goes on. Then the set is lit and run at full flame while we watch the flame shape and the draft, check that the exhaust goes up rather than spilling into the room, and take a carbon monoxide reading. If the set has a remote or a wall switch, we wire and test that too. You get a written note of what was fitted, with the model of set and the clamp position on the damper.

Sets range from plain to elaborate, and the burner, the log count and the controls account for most of the spread, so the figure firms up when your choice of set does. On top of that come any firebox or damper repairs and the gas line work, which depend on what we find. We give you one written figure that names each part. If you later want more heat than an open fireplace with logs can give, the same fireplace can take a sealed insert, and our inserts page explains that option. To start, use the form to tell us the rough width of your fireplace opening, whether there is a gas key near the hearth today, and whether the fireplace has been used for wood lately. Set options get talked through at the measuring visit.

How Hewitt Chimney Group Runs a Job

Read the Wall

Brick, joints and crown judged before any price

Mix on Paper

The mortar type named in every scope

Price Before Work

Changes shown and approved before we go on

Photos Both Ends

Shots of the joints as found and as finished

Other Hewitt Work

Chimney Sweep

Flue brushed down to the tile, soot bagged out under negative air, and a mason's eye kept on every joint the rods pass.

Read the service →

Chimney Inspection

A Level 1 look at firebox, flue openings, crown and brick, read the way a mason reads any old wall.

Read the service →

Chimney Repair

Brick, mortar, crown and flue faults on one stack, ranked by a mason and fixed in an order that shuts out water first.

Read the service →

Fireplace Inspection

Firebox brick, refractory joints, hearth extension and mantel clearance measured, with each crack marked on a photo.

Read the service →

Fireplace Repair

Burnt-out firebox joints, split firebrick, loose hearth tile and sagging lintels rebuilt in materials rated for direct heat.

Read the service →

Chimney Level 2 Inspection

A recorded scan from firebox to flue top, plus the hidden stretches of brick above and below the rooms, for $370.

Read the service →

Chimney Cap Installation

Steel or copper caps fitted onto a crown that can carry them, quoted after we measure by size, metal and flue count. Cap size, metal and flue count shape the price.

Read the service →

Chimney Flashing Repair

Step and counter flashing let into a sawn mortar joint, not glued to the brick face, so the roof seam stays dry.

Read the service →

Chimney Masonry Repair

Tuckpointing, brick replacement and spall repair, with mortar picked so the joint gives way before the brick face does.

Read the service →

Chimney Rebuilds

Stacks taken down to firm brick and relaid with new flue tile, a cast crown and joints tooled to match the original work.

Read the service →

Fireplace Cleaning

Firebox, glass doors, smoke shelf and face cleaned, with soot stains lifted off brick without scouring the surface.

Read the service →

Gas Fireplace Cleaning

Burner ports, ember bed, logs and glass cleaned on vented gas units, then the flame and outside vent looked at.

Read the service →

Gas Fireplace Repair

Pilots, valves, igniters and remotes on gas fireplaces traced to the failed part, with vent and surround looked at too.

Read the service →

Fireplace Remodel

Brick, stone or tile faces rebuilt around a sound firebox, with hearth and mantel laid out by a mason to clearance.

Read the service →

Fireplace Inserts

Gas or wood inserts set into a masonry firebox, with a full-height stainless liner and the old throat closed off.

Read the service →

Pellet Stove Repair

Jammed augers, choked burn pots, worn fans and dirty vent pipe found on pellet stoves and put right part by part.

Read the service →

Wood Stove Repair

Door ropes, glass, firebrick linings, baffles and flue collars on wood stoves renewed, and the chimney connection checked.

Read the service →

Chimney Seismic Retrofit

Unreinforced brick above the roof made less likely to topple, by steel tie-backs or a lighter rebuild, once the mortar can hold.

Read the service →

Chimney Crown Repair

Crowns that were only a mortar wash replaced by a cast slab that overhangs the brick and throws water clear of the stack.

Read the service →

Dryer Vent Cleaning

Lint packed in dryer ducts cleared from the machine to the outside hood, with the run and hood checked for damage.

Read the service →

Chimney Liner Installation

Stainless or cast liners set inside cracked or unlined brick flues, sized to the appliance and sealed at the crown.

Read the service →

Chimney Leak Repair

Water traced to the crown, flashing, joints or brick face and stopped at its source, priced $530 to $3,200.

Read the service →

Chimney Waterproofing

Silane or siloxane repellent soaked into sound, freshly pointed brick, so the face sheds rain and still dries out from inside.

Read the service →

Chimney Damper Repair

Throat dampers freed, rebuilt or replaced, or a top-mount damper fitted at the crown when the cast frame has failed.

Read the service →

Chimney Chase Cover

Rusted or sagging metal lids on wooden chimney chases replaced with welded stainless made to measure, with a cross-break.

Read the service →
Call (951) 523-0165